Error Codes
Code |
Description |
Parameters that trigger the error |
Possible Cause(s) |
---|---|---|---|
E-3 |
Motor error |
No cavity motor rotation detected for greater than 30 seconds. |
1. Connection between Variable Frequency Drive (VFD) and control board |
E-10 |
Sensor short |
Short circuit detected on sensor wires. |
1. Sensor connection |
E-11 |
Sensor open |
Cavity air sensor reading > 650°F (343°C). |
1. Sensor connection |
E-30 |
Unit under temperature |
Cavity temperature remains 25°F (14°C) below target for more than 90 minutes. |
Troubleshoot heating element |
E-31 |
Electronics over temperature |
Control board temperature exceeds 158°F (70°C) and/or interface board temperature exceeds 184°F (84°C). |
1. Cooling fan filters blocked or dirty |
E-87 |
Gas lockout |
Loss of flame three times within 5 minutes. |
Lack of fuel pressure. |
E-88 |
Ignition module/valve failure |
Two, 4-second tries for light at the ignition module with a 30-second delay between. |
1. Valve status is not open after call for heat. |
E-90 |
Gas combustion blower speed failure |
Blower RPM is outside +/- 10% of expected RPMs at start of call for heat, or post-ramping when the end speed is reached. |
1. Power supply cable is not connected to blower motor. |
E-94 |
Interface Board - Control Board communication error |
No signal transfer for more than 5 seconds between the interface board and the control board. |
1. Connection of modbus cable |
E-108 |
Bi-metal thermostat open |
Open circuit detected across bi-metal switch. |
1. Cooling fan filters blocked or dirty |
E-109 |
High limit error Note: Contact an authorized |
Open circuit detected across high limit switch. |
1. Jet plate(s) improperly installed |